Updated values for control and sensitivity samples
This commit is contained in:
parent
077d07a4fe
commit
6e891ffc09
@ -84,13 +84,15 @@ The filter will then be placed in a funnel that is supported in such a way as to
|
||||
|
||||
The solubility of sucrose is fairly high: \SI{2.01}{\gram/\mL}. Sodium chloride is slightly less soluble: \SI{0.36}{\gram/\mL}. To dissolve \SI{25}{\milli\gram} of sucrose would require approximately \SI{12.5}{\milli\liter} of water, whereas to dissolve \SI{25}{\milli\gram} of sodium chloride would require approximately \SI{70}{\milli\liter} of water. Therefore, the amount of water that will be poured over the samples will be \SI{300}{\milli\liter}, which has been proven sufficient in method development to fully dissolve and wash away that amount of sodium chloride and sucrose.
|
||||
|
||||
To confirm this, three control samples will also be tested: \SI{25}{\milli\gram} of sucrose, \SI{25}{\milli\gram} of sodium chloride, and \SI{25}{\milli\gram} of a 50/50 mix by volume of sucrose and sodium chloride. The expected recovery of these samples is less than \num{2}{\unit\percent}.
|
||||
To confirm this, three control samples will also be tested: \SI{25}{\milli\gram} of sucrose, \SI{25}{\milli\gram} of sodium chloride, and \SI{25}{\milli\gram} of a 50/50 mix by volume of sucrose and sodium chloride. The expected recovery of these samples is less than \num{2}{\unit\percent}.
|
||||
|
||||
Additionally, a control sample consisting entirely of a salt-free/sugar-free blend (e.g., Mrs. Dash or similar) will be tested. The expected recovery is \numrange{95}{100}{\unit\percent}.
|
||||
|
||||
The accepted discrepancy in the weighing of all samples (control, sensitivity, and test) will be \SI{\pm 0.5}{\gram}.
|
||||
|
||||
Due to the lack of a calibrated oven, samples will be allowed to dry in a draft-free location at room temperature. Weights will be recorded daily beginning on the third day after (T=3) after the samples are washed (T=0). When two concurrent weighings are within \SI{\pm 0.1}{\gram}, the sample will be considered to be thoroughly dry and the second reading will will be used in further calculations.
|
||||
|
||||
\paragraph{Initial Values of Control and Sensitivity Samples} The masses for the control and sensitivity samples are in table \ref{tb:cont_rec_mass}. Because of the high density of these samples, approximately \SI{25}{\gram} of each sample was used.
|
||||
\paragraph{Initial Values of Control and Sensitivity Samples} The masses for the control and sensitivity samples are in table \ref{tb:cont_rec_mass}. Because of the high density of the salt/sugar and sensitivity samples, approximately \SI{25}{\gram} of each sample was used. Because the salt-free blend is also sugar free and consists entirely of botanical elements, only \SI{15}{\gram} of this sample was used.
|
||||
|
||||
\begin{longtblr}
|
||||
[
|
||||
@ -99,19 +101,20 @@ Due to the lack of a calibrated oven, samples will be allowed to dry in a draft-
|
||||
% theme = {custom1}
|
||||
]{
|
||||
width = {\columnwidth},
|
||||
colspec = { X[2,l] X[1,c] },
|
||||
colspec = { X[5,l] X[1,c] X[2,c] },
|
||||
hlines = {0.5pt,solid},
|
||||
vline{1,3} = {0.5pt,solid},
|
||||
vline{1,4} = {0.5pt,solid},
|
||||
rows = {5mm, m, rowsep=1.5pt},
|
||||
rowhead = 1,
|
||||
cells = {font=\fontsize{9pt}{12pt}\selectfont},
|
||||
row{1} = {font=\bfseries},
|
||||
}
|
||||
Sample & Initial Mass (g) \\
|
||||
100\% Salt & X \\
|
||||
100\% Sugar & X \\
|
||||
50/50\% Salt/Sugar Blend & X \\
|
||||
100\% Salt-Free Blend & X \\
|
||||
Sample & Label & Initial Mass (g) \\
|
||||
100\% Salt & C1 & 25.36 \\
|
||||
100\% Sugar & C2 & 25.27 \\
|
||||
50/50\% Salt/Sugar Blend & C3 & 25.45 \\
|
||||
100\% Seasoning Salt & Sens & 25.13 \\
|
||||
100\% Salt-Free Blend & C4 & 15.36 \\
|
||||
\end{longtblr}
|
||||
|
||||
\end{multicols}
|
||||
|
Loading…
Reference in New Issue
Block a user