Typos pp. 1309-37
This commit is contained in:
parent
08de52dcab
commit
ae6dc116d2
@ -56,7 +56,7 @@ SPSCODE = BIT9
|
||||
|
||||
COUNT* $$/IMODE
|
||||
IMUZERO INHINT # ROUTINE TO ZERO ICDUS.
|
||||
CS DSPTAB +11D # DON'T ZERO CDUS IS IMU IN GIMBAL LOCK AND
|
||||
CS DSPTAB +11D # DON'T ZERO CDUS IF IMU IN GIMBAL LOCK AND
|
||||
MASK BITS4&6 # COARSE ALIGN (GIMBAL RUNAWAY PROTECTION)
|
||||
CCS A
|
||||
TCF IMUZEROA
|
||||
@ -403,7 +403,7 @@ PIPFREE INHINT # PROGRAM DONE WITH PIPAS. DON'T LIGHT
|
||||
MASK BIT1
|
||||
ADS IMODES30
|
||||
|
||||
MASK BIT10 # IF PIP FAIL ON, DO PROG ALARM AND RESET
|
||||
MASK BIT10 # IF PIP FAIL ON, DO PROG ALSRM AND RESET
|
||||
CCS A # ISS WARNING.
|
||||
TCF MODEEXIT
|
||||
|
||||
@ -415,9 +415,9 @@ PIPFREE INHINT # PROGRAM DONE WITH PIPAS. DON'T LIGHT
|
||||
TCF PIPFREE2
|
||||
|
||||
# Page 1319
|
||||
# THE FOLLOWING ROUTINE TORQUES THE IRIGS ACCORDING TO DOUBLE PRECISION INPUTS IN THE SIXE REGISTERS
|
||||
# THE FOLLOWING ROUTINE TORQUES THE IRIGS ACCORDING TO DOUBLE PRECISION INPUTS IN THE SIX REGISTERS
|
||||
# BEGINNING AT THE ECADR ARRIVING IN A. THE MINIMUM SIZE OF ANY PULSE TRAIN IS 16 PULSES (.25 CDU COUNTS). THE
|
||||
# UNSENT PORTION OF THE COMMAND IS LEFT INTACT AT THE INPUT COMMAND REGISTERS.
|
||||
# UNSENT PORTION OF THE COMMAND IS LEFT INTACT IN THE INPUT COMMAND REGISTERS.
|
||||
|
||||
EBANK= 1400 # VARIABLE, ACTUALLY.
|
||||
|
||||
@ -514,7 +514,7 @@ STRTGYR2 CA LGYRO # JUMP ON PHASE COUNTER IN BITS 13-14.
|
||||
CAF LGWAKE # WAKE A POSSIBLE SLEEPING JOB.
|
||||
TC JOBWAKE
|
||||
|
||||
NORESET TCF IMUFINED # DO NOT RESET POWER SUPPLY.
|
||||
NORESET TCF IMUFINED # DO NOT RESET POWER SUPPLY
|
||||
# Page 1322
|
||||
-2 CS FOUR # SPECIAL ENTRY TO REGRESS LGYRO FOR X.
|
||||
ADS LGYRO
|
||||
@ -701,8 +701,8 @@ CAGETSTQ CS IMODES30 # SKIP IF IMU NOT BEING CAGED.
|
||||
INCR Q
|
||||
TC Q
|
||||
|
||||
CAGETSTJ CS IMODES30 # IF DURING MODE SWITCH INITIALIZATION.
|
||||
MASK BIT6 # IT IS FOUND THAT THE IMU IS BEING CAGED.
|
||||
CAGETSTJ CS IMODES30 # IF DURING MODE SWITCH INITIALIZATION
|
||||
MASK BIT6 # IT IS FOUND THAT THE IMU IS BEING CAGED,
|
||||
CCS A # SET IMUCADR TO -0 TO INDICATE OPERATION
|
||||
TC Q # COMPLETE BUT FAILED. RETURN IMMEDIATELY
|
||||
|
||||
@ -749,53 +749,49 @@ ENDMODE CA RUPTREG3 # -0 INDICATES OPERATION COMPLETE BUT
|
||||
# Page 1329
|
||||
# GENERAL STALLING ROUTINE. USING PROGRAMS COME HERE TO WAIT FOR I/O COMPLETION.
|
||||
#
|
||||
# PROGRAM DESCRIPTION DATE -- 21 FEB 1967
|
||||
# PROGRAM DESCRIPTION DATE- 21 FEB 1967
|
||||
# LOG SECTION IMU MODE SWITCHING
|
||||
# MOD BY -- R. MELANSON TO ADD DOCUMENTATION ASSEMBLY SUNDISK REV. 82
|
||||
# MOD BY- R.MELANSON TO ADD DOCUMENTATION ASSEMBLY SUNDISK REV. 82
|
||||
#
|
||||
# FUNCTIONAL DESCRIPTION --
|
||||
# FUNCTIONAL DESCRIPTION-
|
||||
# TO DELAY FURTHER EXECUTION OF THE CALLING ROUTINE UNTIL ITS SELECTED
|
||||
# I/O FUNCTION IS COMPLETE. THE FOLLOWING CHECKS ON THE CALLING ROUTINES
|
||||
# MODEECADR ARE MADE AND ACTED UPON.
|
||||
# I/O FUNCTION IS COMPLETE.THE FOLLOWING CHECKS ON THE CALLING ROUTINE:S
|
||||
# MODECADR ARE MADE AND ACTED UPON.
|
||||
# 1) +0 INDICATES INCOMPLETE I/O OPERATION.CALLING ROUTINE IS PUT TO
|
||||
# SLEEP.
|
||||
# 2) -1 INDICATES COMPLETED I/O OPERATION. STALL BYPASSES JOBSLEEP
|
||||
# CALL AND RETURNS TO CALLING ROUTINE AT L+3.
|
||||
# CALL AND RETURNS TO CALLING ROUTINE AT L+3
|
||||
# 3) -0 INDICATES COMPLETED I/O WITH FAILURE. STALL CLEARS MODECADR
|
||||
# AND RETURNS TO CALLING ROUTINE AT L+2.
|
||||
# 4) VALUE GREATER THAN 0 INDICATES TWO ROUTINES CALLING FOR USE OF
|
||||
# SAME DEVICE. STALL EXITS TO ABORT WHICH EXECUTES A PROGRAM
|
||||
# RESTART WHICH IN TURN CLEARS ALL MODECADR REGISTERS.
|
||||
#
|
||||
# CALLING SEQUENCE --
|
||||
# CALLING SEQUENCE-
|
||||
# L TC BANKCALL
|
||||
# L+1 CADR (ONE OF 5 STALL ADDRESSES. I.E., IMUSTALL, OPTSTALL, RADSTALL,
|
||||
# L+1 CADR (ONE OF 5 STALL ADDRESSES I.E. IMUSTALL,OPTSTALL,RADSTALL,
|
||||
# AOTSTALL,OR ATTSTALL)
|
||||
#
|
||||
# NORMAL-EXIT MODE --
|
||||
# NORMAL-EXIT MODE-
|
||||
# TCF JOBSLEEP OR TCF MODEXIT
|
||||
#
|
||||
# ALARM OR ABORT EXIT MODE --
|
||||
# ALARM OR ABORT EXIT MODE-
|
||||
# TC ABORT
|
||||
#
|
||||
# OUTPUT --
|
||||
# OUTPUT-
|
||||
# MODECADR= CADR IF JOBSLEEP
|
||||
# MODECADR=+0 IF I/O COMPLETE
|
||||
# BUF2=L+3 IF I/O COMPLETE AND GOOD.
|
||||
# BUF2=L+2 IF I/O COMPLETE BUT FAILED.
|
||||
#
|
||||
# ERASABLE INITIALIZATION --
|
||||
# ERASABLE INITIALIZATION-
|
||||
# BUF2 CONTAINS RETURN ADDRESS PLUS 1,(L+2)
|
||||
# BUF2+1 CONTAINS FBANK VALUE OF CALLING ROUTINE.
|
||||
# MODECADR OF CALLING ROUTINE CONTAINS +0,-1,-0 OR CADR RETURN ADDRESS.
|
||||
#
|
||||
# DEBRIS --
|
||||
# DEBRIS-
|
||||
# RUPTREG2 AND CALLING ROUTINE MODECADR.
|
||||
|
||||
## [WORKAROUND] OH 2009
|
||||
SBANK= LOWSUPER
|
||||
## [WORKAROUND]
|
||||
|
||||
AOTSTALL CAF ONE # AOT.
|
||||
TC STALL
|
||||
|
||||
@ -815,7 +811,7 @@ STALL INHINT
|
||||
TCF MODESLP # OPERATION INCOMPLETE.
|
||||
TCF MODEGOOD # COMPLETE AND GOOD IF = -1.
|
||||
|
||||
MG2 INDEX RUPTREG2 # COMPLETE FAILED IF -0. RESET TO +0.
|
||||
MG2 INDEX RUPTREG2 # COMPLETE AND FAILED IF -0. RESET TO +0.
|
||||
TS MODECADR # RETURN TO CALLER.
|
||||
TCF MODEEXIT
|
||||
|
||||
@ -823,7 +819,7 @@ MODEGOOD CCS A # MAKE SURE INITIAL STATE -1.
|
||||
TCF MODABORT
|
||||
|
||||
INCR BUF2 # IF SO, INCREMENT RETURN ADDRESS AND
|
||||
TCF MG2 # RETURN IMMEDIATELY, SETTIN CADR = +0.
|
||||
TCF MG2 # RETURN IMMEDIATELY, SETTING CADR = +0.
|
||||
|
||||
MODESLP TC MAKECADR # CALL FROM SWITCHABLE FIXED ONLY.
|
||||
INDEX RUPTREG2
|
||||
@ -849,7 +845,7 @@ GOMANUR CA ATTCADR # IS KALCMANU FREE
|
||||
EXTEND
|
||||
BZF +3
|
||||
|
||||
TC P00DOO # NO
|
||||
TC POODOO # NO
|
||||
OCT 1210 # 2 TRYING TO USE SAME DEVICE
|
||||
|
||||
+3 EXTEND
|
||||
@ -862,7 +858,7 @@ GOMANUR CA ATTCADR # IS KALCMANU FREE
|
||||
|
||||
CA PRIORITY
|
||||
MASK PRIO37
|
||||
TS ATTPRIO # SAVE USER'S PRIO
|
||||
TS ATTPRIO # SAVE USERS PRIO
|
||||
|
||||
CAF KALEBCON # SET EBANK FOR KALCMAN3
|
||||
TS EBANK
|
||||
@ -873,34 +869,33 @@ KALEBCON ECADR BCDU
|
||||
# Page 1332
|
||||
# PROGRAM DESCRIPTION
|
||||
# IMU STATUS CHECK ROUTINE R02 (SUBROUTINE UTILITY)
|
||||
# MOD NO -- 1
|
||||
# MOD BY -- N.BRODEUR
|
||||
#
|
||||
# MOD NO - 1
|
||||
# MOD BY - N.BRODEUR
|
||||
# FUNCTIONAL DESCRIPTION
|
||||
#
|
||||
# TO CHECK WHETHER IMU IS ON AND IF ON WHETHER IT IS ALIGNED TO AN
|
||||
# ORIENTATION KNOWN BY THE CMC. TO REQUEST SELECTION OF THE APPROPRIATE
|
||||
# PROGRAM IF THE IMU IS OFF OR NOT ALIGNED TO AN ORIENTATION KNOWN BY THE
|
||||
# CMC. CALLED THROUGH BANKCALL
|
||||
# CALLING SEQUENCE-
|
||||
#
|
||||
# CALLING SEQUENCE --
|
||||
# L TC BANKCALL
|
||||
# L+1 CADR R02BOTH
|
||||
#
|
||||
# SUBROUTINES CALLED
|
||||
#
|
||||
# VARALARM
|
||||
# FLAGUP
|
||||
#
|
||||
# NORMAL EXIT MODES
|
||||
#
|
||||
# AT L+2 OF CALLING SEQUENCE
|
||||
#
|
||||
# ALARM OR ABORT EXIT MODES
|
||||
# GOTOP00H, WITH ALARM
|
||||
#
|
||||
# GOTOPOOH, WITH ALARM
|
||||
# ERASABLE INITIALIZATION REQUIRED
|
||||
# NONE
|
||||
#
|
||||
# NONE
|
||||
# DEBRIS
|
||||
# CENTRALS -- A,Q,L
|
||||
#
|
||||
# CENTRALS-A,Q,L
|
||||
|
||||
BANK 34
|
||||
SETLOC R02
|
||||
@ -920,7 +915,7 @@ R02BOTH CAF REFSMBIT
|
||||
AD OCT220 # SEND REFSMM ALARM
|
||||
TC VARALARM
|
||||
|
||||
TC GOTOP00H
|
||||
TC GOTOPOOH
|
||||
|
||||
R02ZERO TC UPFLAG
|
||||
# Page 1333
|
||||
@ -929,7 +924,7 @@ R02ZERO TC UPFLAG
|
||||
OCT220 OCT 220
|
||||
|
||||
# Page 1334
|
||||
# PROGRAM DESCRIPTION: P06 10 FEB 67
|
||||
# PROGRAM DESCRIPTION P06 10FEB67
|
||||
#
|
||||
# TRANSFER THE ISS/CMC FROM THE OPERATE TO THE STANDBY CONDITION.
|
||||
#
|
||||
@ -946,7 +941,7 @@ OCT220 OCT 220
|
||||
# FLAGDOWN
|
||||
#
|
||||
# Page 1335
|
||||
# PRESTAND PREPARES FOR STANDBY BY SNAPSHOTTING THE SCALER AND TIME1 TIME2.
|
||||
# PRESTAND PREPARES FOR STANDBY BY SNAPSHOTTING THE SCALER AND TIME1 TIME2
|
||||
# THE LOW 5 BITS OF THE SCALER ARE INSPECTED TO INSURE COMPATIBILITY
|
||||
# BETWEEN THE SCALER READING AND THE TIME1 TIME2 READING.
|
||||
|
||||
@ -1002,7 +997,7 @@ OCT62 EQUALS .5SEC # DEC 50 = OCT 62
|
||||
# DATA. OTHERWISE, THE RETURN IS TO L+2 TO PROCEED. ROUTINE ALSO PREPARES
|
||||
# THE SCALER READING FOR COMPUTATION OF THE INCREMENT TO UPDATE T1T2. (THE
|
||||
# 10 MS BIT (BIT 6) OF THE SCALER IS INCREMENTED 5 MS OUT OF PHASE FROM
|
||||
# T1.0 ADDITION OF 5 MS (BIT 5) TO THE SCALER READING HAS THE EFFECT OF
|
||||
# T1.) ADDITION OF 5 MS (BIT 5) TO THE SCALER READING HAS THE EFFECT OF
|
||||
# ADJUSTING BIT 6 IN THE SCALER TO BE IN PHASE WITH BIT 1 OF T1. THE LOW 5
|
||||
# BITS OF THE SCALER READING ARE THEN SET TO ZERO, TO TRUNCATE THE SCALER
|
||||
# DATA TO 10 MS. RESULTS ARE STORED IN MPAC, +1.
|
||||
@ -1035,7 +1030,7 @@ SCALPREP EXTEND
|
||||
|
||||
COUNT* $$/P05
|
||||
|
||||
POSTAND CS BIT11 # RECOVER TIME AFTER STANDBY
|
||||
POSTAND CS BIT11 # RECOVER TIME AFTER STANDBY.
|
||||
EXTEND
|
||||
WAND CHAN13 # CLEAR STANDBY ENABLE BIT
|
||||
INHINT
|
||||
@ -1046,9 +1041,9 @@ POSTAND CS BIT11 # RECOVER TIME AFTER STANDBY
|
||||
TC POSTAND +3 # T1,T2,SCALER NOT COMPATIBLE
|
||||
EXTEND # T1,T2 AND SCALER OK
|
||||
DCS SCALSAVE
|
||||
DAS MPAC # FORM DP DIFFERENCE OF POST-STANDBY SCALER
|
||||
DAS MPAC # FORM DP DIFFERENCE OF POSTSTANDBY SCALER
|
||||
# Page 1337
|
||||
CAF BIT10 # MINUS PRE-STANDBY SCALER AND SHIFT RIGHT
|
||||
CAF BIT10 # MINUS PRESTANDBY SCALER AND SHIFT RIGHT
|
||||
TC SHORTMP # 5 TO ALIGN BITS WITH TIME1TIME2.
|
||||
CAF ZERO
|
||||
TS MPAC +2 # NEEDED FOR TP AGREE
|
||||
@ -1060,7 +1055,7 @@ POSTAND CS BIT11 # RECOVER TIME AFTER STANDBY
|
||||
CAF BIT10 # BIT 10 TO HIGH DIFF TO CORRECT.
|
||||
ADS MPAC
|
||||
POSTCOM EXTEND # C(MPAC,+1) IS MAGNITUDE OF DELTA SCALER.
|
||||
DCA TIME2SAV # PRE-STANDBY TIME1 TIME2
|
||||
DCA TIME2SAV # PRESTANDBY TIME1TIME2
|
||||
DAS MPAC
|
||||
TC TPAGREE # FORCE SIGN AGREEMENT
|
||||
DXCH MPAC # UPDATED VALUE FOR T1,T2.
|
||||
@ -1068,5 +1063,5 @@ POSTCOM EXTEND # C(MPAC,+1) IS MAGNITUDE OF DELTA SCALER.
|
||||
TC DOWNFLAG # CLEAR NODOFLAG
|
||||
ADRES NODOFLAG
|
||||
|
||||
TC GOTOP00H
|
||||
TC GOTOPOOH
|
||||
|
||||
|
Loading…
Reference in New Issue
Block a user