Apollo-11/IMU_COMPENSATION_PACKAGE.s
2016-07-07 04:47:26 -04:00

371 lines
9.2 KiB
ArmAsm

# Copyright: Public domain.
# Filename: IMU_COMPENSATION_PACKAGE.agc
# Purpose: Part of the source code for Colossus 2A, AKA Comanche 055.
# It is part of the source code for the Command Module's (CM)
# Apollo Guidance Computer (AGC), for Apollo 11.
# Assembler: yaYUL
# Contact: Ron Burkey <info@sandroid.org>.
# Website: www.ibiblio.org/apollo.
# Pages: 297-306
# Mod history: 2009-05-08 RSB Adapted from the Colossus249/ file of the
# same name, using Comanche055 page images/
# 2009-05-21 RSB In IRIGZ, PRIO17 corrected to PRIO21.
#
# This source code has been transcribed or otherwise adapted from digitized
# images of a hardcopy from the MIT Museum. The digitization was performed
# by Paul Fjeld, and arranged for by Deborah Douglas of the Museum. Many
# thanks to both. The images (with suitable reduction in storage size and
# consequent reduction in image quality as well) are available online at
# www.ibiblio.org/apollo. If for some reason you find that the images are
# illegible, contact me at info@sandroid.org about getting access to the
# (much) higher-quality images which Paul actually created.
#
# Notations on the hardcopy document read, in part:
#
# Assemble revision 055 of AGC program Comanche by NASA
# 2021113-051. 10:28 APR. 1, 1969
#
# This AGC program shall also be referred to as
# Colossus 2A
# Page 297
BANK 7
SETLOC IMUCOMP
BANK
EBANK= NBDX
COUNT 06/ICOMP
1/PIPA CAF LGCOMP # SAVE EBANK OF CALLING PROGRAM
XCH EBANK
TS MODE
CCS GCOMPSW # BYPASS IF GCOMPSW NEGATIVE
TCF +3
TCF +2
TCF IRIG1 # RETURN
INHINT # ASSURE COMPLETE COMPENSATION OF DELV'S
# FOR DOWNLINK.
1/PIPA1 CAF FOUR # PIPAZ, PIPAY, PIPAX
TS BUF +2
INDEX BUF +2
CA PIPASCF # (P.P.M.) X 2(-9)
EXTEND
INDEX BUF +2
MP DELVX # (PP) X 2(+14) NOW (PIPA PULSES) X 2(+5)
TS Q # SAVE MAJOR PART
CA L # MINOR PART
EXTEND
MP BIT6 # SCALE 2(+9) SHIFT RIGHT 9
INDEX BUF +2
TS DELVX +1 # FRACTIONAL PIPA PULSES SCALED 2(+14)
CA Q # MAJOR PART
EXTEND
MP BIT6 # SCALE 2(+9) SHIFT RIGHT 9
INDEX BUF +2
DAS DELVX # (PIPAI) + (PIPAI)(SF)
INDEX BUF +2
CS PIPABIAS # (PIPA PULSES)/(CS) X 2(-8) *
EXTEND
MP 1/PIPADT # (CS) X 2(+8) NOW (PIPA PULSES) X 2(+0) *
EXTEND
MP BIT1 # SCALE 2(+14) SHIFT RIGHT 14 *
INDEX BUF +2
DAS DELVX # (PIPAI) + (PIPAI)(SFE) - (BIAS)(DELTAT)
CCS BUF +2 # PIPAZ, PIPAY, PIPAX
# Page 298
AD NEG1
TCF 1/PIPA1 +1
NOOP # LESS THAN ZERO IMPOSSIBLE
RELINT
# Page 299
IRIGCOMP TS GCOMPSW # INDICATE COMMANDS 2 PULSES OR LESS.
TS BUF # INDEX COUNTER. IRIGX, IRIGY, IRIGZ.
IRIGX EXTEND
DCS DELVX # (PIPA PULSES) X 2(+14)
DXCH MPAC
CA ADIAX # (GYRO PULSES)/(PIPA PULSE) X 2(-3) *
TC GCOMPSUB # -(ADIAX)(PIPAX) (GYRO PULSES) X 2(+14)
EXTEND #
DCS DELVY # (PIPA PULSES) X 2(+14)
DXCH MPAC #
CS ADSRAX # (GYRO PULSES)/(PIPA PULSE) X 2(-3) *
TC GCOMPSUB # -(ADSRAX)(PIPAY) (GYRO PULSES) X 2(+14)
# EXTEND # ***
# DCS DELVY # *** (PIPA PULSES) X 2(+14)
# DXCH MPAC # ***
# CA ADOAX # *** (GYRO PULSES)/(PIPA PULSE) X 2(-3) *
# TC GCOMPSUB # *** -(ADOAX)(PIPAZ) (GYRO PULSES) X 2(+14)
CS NBDX # (GYRO PULSES)/(CS) X 2(-3)
TC DRIFTSUB # -(NBDX)(DELTAT) (GYRO PULSES) X 2(+14)
IRIGY EXTEND
DCS DELVY # (PIPA PULSES) X 2(+14)
DXCH MPAC
CA ADIAY # (GYRO PULSES)/(PIPA PULSE) X 2(-3) *
TC GCOMPSUB # -(ADIAY)(PIPAY) (GYRO PULSES) X 2(+14)
EXTEND
DCS DELVZ # (PIPA PULSES) X 2(+14)
DXCH MPAC
CS ADSRAY # (GYRO PULSES)/(PIPA PULSE) X 2(-3) *
TC GCOMPSUB # +(ADSRAY)(PIPAZ) (GYRO PULSES) X 2(+14)
# EXTEND # ***
# DCS DELVX # *** (PIPA PULSES) X 2(+14)
# DXCH MPAC # ***
# CA ADOAY # *** (GYRO PULSES)/(PIPA PULS) X 2(-3) *
# TC GCOMPSUB # *** -(ADOAY)(/PIPAX) (GYRO PULSES) X 2(+14)
CS NBDY # (GYRO PULSES)/(CS) X 2(-5)
TC DRIFTSUB # -(NBDY)(DELTAT) (GYRO PULSES) X 2(+14)
IRIGZ EXTEND
DCS DELVY # (PIPA PULSES) X 2(-14)
DXCH MPAC
CA ADSRAZ # (GYRO PULSES)/(PIPA PULSE) X 2(-3) *
# Page 300
TC GCOMPSUB # -(ADSRAZ)(PIPAY) (GYRO PULSES) X 2(+14)
EXTEND
DCS DELVZ # (PIPA PULSES) X 2(+14)
DXCH MPAC
CA ADIAZ # (GYRO PULSES)/(PIPA PULSE) X 2(-3) *
TC GCOMPSUB # -(ADIAZ)(PIPAZ) (GYRO PULSES) X 2(+14)
# EXTEND # ***
# DCS DELVX # *** (PIPA PULSE) X 2(+14)
# DXCH MPAC # ***
# CS ADOAZ # *** (GYRO PULSES)/(PIPA PULSE) X 2(-3) *
# TC GCOMPSUB # *** +(ADOAZ)(PIPAX) (GYRO PULSES) X 2(+14)
CA NBDZ # (GYRO PULSES)/(CS) X 2(-5)
TC DRIFTSUB # +(NBDZ)(DELTAT) (GYRO PULSES) X 2(+14)
# Page 301
CCS GCOMPSW # ARE GYRO COMMANDS GREATER THAN 2 PULSES
TCF +2 # YES
TCF IRIG1 # NO
CA PRIO21 # HIGHER THAN SERVICER -- LESS THAN PRELAUNCH
TC NOVAC
EBANK= NBDX
2CADR 1/GYRO
RELINT
IRIG1 CA MODE # SET EBANK FOR RETURN
TS EBANK
TCF SWRETURN
GCOMPSUB XCH MPAC # ADIA OR ADSRA COEFFICIENT ARRIVES IN A
EXTEND # C(MPAC) = (PIPA PULSES) X 2(+14)
MP MPAC # (GYRO PULSES)/(PIPA PULSE) X 2(-3) *
DXCH VBUF # NOW = (GYRO PULSES) X 2(+11) *
CA MPAC +1 # MINOR PART OF PIPA PULSES
EXTEND
MP MPAC # ADIA OR ADSRA
TS L
CAF ZERO
DAS VBUF # NOW = (GYRO PULSES) X 2(+11) *
CA VBUF # PARTIAL RESULT -- MAJOR
EXTEND
MP BIT12 # SCALE 2(+3) SHIFT RIGHT 3 *
INDEX BUF # RESULT = (GYRO PULSES) X 2(+14)
DAS GCOMP # HI(ADIA)(PIPAI) OR HI(ADSRA)(PIPAI)
CA VBUF +1 # PARTIAL RESULT -- MINOR
EXTEND
MP BIT12 # SCALE 2(+3) SHIFT RIGHT 3 *
TS L
CAF ZERO
INDEX BUF # RESULT = (GYRO PULSES) X 2(+14)
DAS GCOMP # (ADIA)(PIPAI) OR (ADSRA)(PIPAI)
TC Q
# Page 302
DRIFTSUB EXTEND
QXCH BUF +1
EXTEND # C(A) = NBD (GYRO PULSES)/(CS) X 2(-5)
MP 1/PIPADT # (CS) X 2(+8) NO (GYRO PULSES) X 2(+3)
LXCH MPAC +1 # SAVE FOR FRACTIONAL COMPENSATION
EXTEND
MP BIT4 # SCALE 2(+11) SHIFT RIGHT 11
INDEX BUF
DAS GCOMP # HI(NBD)(DELTAT) (GYRO PULSES) X 2(+14)
CA MPAC +1 # NOW MINOR PART
EXTEND
MP BIT4 # SCALE 2(+11) SHIFT RIGHT 11
TS L
CAF ZERO
INDEX BUF # ADD IN FRACTIONAL COMPENSATION
DAS GCOMP # (NBD)(DELTAT) (GYRO PULSES) X 2(+14)
DRFTSUB2 CAF TWO # PIPAX, PIPAY, PIPAZ
AD BUF
XCH BUF
INDEX A
CCS GCOMP # ARE GYRO COMMANDS 1 PULSE OR GREATER
TCF +2 # YES
TC BUF +1 # NO
MASK NEGONE
CCS A # ARE GYRO COMMANDS GREATER THAN 2 PULSES
TS GCOMPSW # YES -- SET GCOMPSW POSITIVE
TC BUF +1 # NO
# Page 303
1/GYRO CAF FOUR # PIPAZ, PIPAY, PIPAX
TS BUF
INDEX BUF # SCALE GYRO COMMANDS FOR IMUPULSE
CA GCOMP +1 # FRACTIONAL PULSES
EXTEND
MP BIT8 # SHIFT RIGHT 7
INDEX BUF
TS GCOMP +1 # FRACTIONAL PULSES SCALED
CAF ZERO # SET GCOMP = 0 FOR DAS INSTRUCTION
INDEX BUF
XCH GCOMP # GYRO PULSES
EXTEND
MP BIT8 # SHIFT RIGHT 7
INDEX BUF
DAS GCOMP # ADD THESE TO FRACTIONAL PULSES ABOVE
CCS BUF # PIPAZ, PIPAY, PIPAX
AD NEG1
TCF 1/GYRO +1
LGCOMP ECADR GCOMP # LESS THAN ZERO IMPOSSIBLE
CAF LGCOMP
TC BANKCALL
CADR IMUPULSE # CALL GYRO TORQUING ROUTINE
TC BANKCALL
CADR IMUSTALL # WAIT FOR PULSES TO GET OUT
TCF ENDOFJOB # TEMPORARY
GCOMP1 CAF FOUR # PIPAZ, PIPAY, PIPAX
TS BUF
INDEX BUF # RESCALE
CA GCOMP +1
EXTEND
MP BIT8 # SHIFT MINOR PART LEFT 7 -- MAJOR PART = 0
INDEX BUF
LXCH GCOMP +1 # BITS 8-14 OF MINOR PART WERE = 0
CCS BUF # PIPAZ, PIPAY, PIPAX
AD NEG1
TCF GCOMP1 +1
V06N30S VN 0630
TCF ENDOFJOB
# Page 304
NBDONLY CCS GCOMPSW # BYPASS IF GCOMPSW NEGATIVE
TCF +3
TCF +2
TCF ENDOFJOB
INHINT
CCS FLAGWRD2 # PREREAD T3RUPT MAY COINCIDE
TCF ENDOFJOB
TCF ENDOFJOB
TCF +1
CA TIME1 # (CS) X 2(+14)
XCH 1/PIPADT # PREVIOUS TIME
RELINT
COM
AD 1/PIPADT
NBD2 CCS A # CALCULATE ELAPSED TIME.
AD ONE # NO TIME1 OVERFLOW
TCF NBD3 # RESTORE TIME DIFFERENCE AND JUMP
TCF +2 # TIME1 OVERFLOW
TCF ENDOFJOB # IF ELAPSED TIME = 0 (DIFFERENCE = -0)
COM # CALCULATE ABSOLUTE DIFFERENCE
AD POSMAX
NBD3 EXTEND # C(A) = DELTAT (CS) X 2(+14)
MP BIT10 # SHIFT RIGHT 5
DXCH VBUF
EXTEND
DCA VBUF
DXCH MPAC # DELTAT NOW SCALED (CS) X 2(+19)
CAF ZERO
TS GCOMPSW # INDICATE COMMANDS 2 PULSES OR LESS.
TS BUF # INDEX X, Y, Z.
CS NBDX # (GYRO PULSES)/(CS) X 2(-5)
TC FBIASSUB # -(NBOX)(DELTAT) (GYRO PULSES) X 2(+14)
EXTEND
DCS VBUF
DXCH MPAC # DELTAT SCALED (CS) X 2(+19)
CA NBDY # (GYRO PULSES)/(CS) X 2(-5)
TC FBIASSUB # -(NBDY)(DELTAT) (GYRO PULSES) X 2(+14)
EXTEND
DCS VBUF
DXCH MPAC # DELTAT SCALED (CS) X 2(+19)
CS NBDZ # (GYRO PULSES)/(CS) X 2(-5)
TC FBIASSUB # +(NBDZ)(DELTAT) (GYRO PULSES) X 2(+14)
# Page 305
CCS GCOMPSW # ARE GYRO COMMANDS GREATER THAN 2 PULSES
TCF 1/GYRO # YES
TCF ENDOFJOB # NO
# Page 303
FBIASSUB XCH Q
TS BUF +1
CA Q # NBD SCALED (GYRO PULSES)/(CS) X 2(-5)
EXTEND
MP MPAC # DELTAT SCALED (CS) X 2(+19)
INDEX BUF
DAS GCOMP # HI(NBD)(DELTAT) (GYRO PULSES) X 2(+14)
CA Q # NO FRACTIONAL PART
EXTEND
MP MPAC +1
TS L
CAF ZERO
INDEX BUF
DAS GCOMP # (NBD)(DELTAT) (GYRO PULSES) X 2(+14)
TCF DRFTSUB2 # CHECK MAGNITUDE OF COMPENSATION
LASTBIAS TC BANKCALL
CADR PIPUSE
CCS GCOMPSW # BYPASS IF GCOMPSW NEGATIVE
TCF +3
TCF +2
TCF ENDOFJOB
CAF PRIO31 # 2 SECONDS SCALED (CS) X 2(+8)
XCH 1/PIPADT
COM
AD PIPTIME1 +1 # TIME AT PIPA1 =0
TCF NBD2